X

Our Products

  • Filters

Skylights & Wall Lights

An estimated 60% light-transmitting capacity sets a useful reference for these translucent GRP skylights and wall lights. Made to match Kirby rib and wall panels, they introduce transmitted light through the building envelope. The figure is an estimate, not a specified certified test result.
Product typesSkylights and wall lights
MaterialTranslucent GRP
Panel matchingKirby rib and wall panels
Light transmissionEstimated 60%
Skylights and wall lights use translucent glass-reinforced plastic (GRP) and are intended to match Kirby rib and wall panels. Their light-transmitting capacity is estimated at 60%; no tested transmission method or panel dimensions are specified.
Price upon request

Walk Doors (Single or Double)

A 2134 mm door height anchors both specified walk-door width options. These electro-galvanized steel walk doors use 20-gauge steel with a polyurethane-insulation core and a provided door fixture. Single and double configurations are identified, with 915 mm and 1830 mm widths to clarify against the intended opening.
ConfigurationSingle or double
Width options915 mm or 1830 mm
Height2134 mm
Steel designation20 gauge
Door materialElectro-galvanized steel
CorePolyurethane insulation
Door fixtureProvided
Walk doors in single or double configurations, made from 20-gauge electro-galvanized steel with polyurethane-insulation cores and supplied door fixtures. Stated width options are 915 mm and 1830 mm; stated height is 2134 mm. Width allocation by configuration is not defined.
Price upon request

Sliding Doors

At a large hangar or warehouse opening, the door can travel sideways instead of swinging on hinges. These sliding doors for hangars and warehouses use top-mounted rollers resting on brackets to permit that movement. Both single-leaf and double-leaf configurations are identified for project planning.
ApplicationsHangars and warehouses
Opening requirementLarger building openings
MovementSliding, not hinged
Roller positionTop of doors
Roller supportBrackets
Leaf configurationsSingle leaf or double leaf
Sliding doors intended for larger hangar and warehouse openings operate without hinges. Door-top rollers supported on brackets enable sideways travel. Single-leaf and double-leaf configurations are identified; no opening dimensions or door material are specified.
Price upon request

Turbovents

A turbovent and its roof-panel connection need to be considered together. These roof turbovents with GRP curb feature the low-silhouette Kirby 'C' whirlwind extract assembly, a spun-aluminium non-return shutter and a one-piece base and throat. The moulded curb is intended to suit Kirby roof panels.
Ventilator referenceKirby ‘C’ whirlwind
ProfileLow silhouette
FunctionExtraction ventilation
ShutterSpun-aluminium non-return
Base and throatOne-piece construction
Mounting curbMoulded GRP roof curb
Stated panel fitKirby roof panels
Low-silhouette Kirby 'C' whirlwind extract turbovents are mounted on moulded GRP roof curbs intended for Kirby roof panels. Each specified assembly includes a spun-aluminium non-return shutter and a one-piece base and throat.
Price upon request

Roof Curbs

Reinforced plastic forms the curb enclosure; Kirby rib panels define its intended roof fit. These reinforced plastic roof curbs accommodate ducts and other roof projections. For international building projects, the roof profile and the projection geometry are the key details to align before an enclosure is specified.
Product typeRoof curb enclosure
MaterialReinforced Plastic
Material typeGlass Fibre Reinforced Plastic (GRP) - manufacturer reference
Material thickness2 mm brochure reference; other versions may differ - confirmation required
Opening sizes600 x 600 mm, 900 x 900 mm, 1200 x 1200 mm - manufacturer reference
Opening shapeSquare
Roof compatibilityKirby rib roof panels
Primary applicationDucts and other roof projections
FunctionProvides an enclosure around roof projections
Reinforced-plastic roof curbs form enclosures around ducts and other roof projections. Their specified panel interface is the Kirby rib roof profile. Exact dimensions and the reinforced-plastic formulation are not provided.
Price upon request

Roof Jacks

Roof jacks provide enclosures for pipes and stacks projecting from a roof. Their stated function includes allowing safe working on the roof around these projections. Because the enclosure type and dimensions are not yet defined, buyers should establish the exact roof-jack arrangement before selecting it for a project.
Product typeRoof penetration enclosure
ApplicationPipes and stacks projecting through building roofs
FunctionEnclosure around roof projections
MaterialGlass Reinforced Plastic (GRP) - manufacturer reference
Material thickness2 mm brochure reference; 3 mm in another technical handbook - confirmation required
Opening diameter50 mm to 300 mm - manufacturer reference
Opening shapeCircular
Roof compatibilityKirby roof panels - profile confirmation required
Primary benefitEncloses roof projections and supports safer roof working conditions
Roof jacks enclose pipes or stacks projecting from a roof and are intended to allow safe work around those projections. No material, dimensions, installation method or safety rating is specified.
Price upon request

Ridge Ventilators

Along the roof ridge, natural ventilation depends on a suitable opening and its controls. These gravity ridge ventilators with bird screen include a mechanically controlled damper and are intended to ventilate the building naturally. The combination gives buyers a clear assembly to evaluate for their roof design.
Ventilator typeGravity-type ridge ventilator
VentilationNatural building ventilation
Bird screenProvided
DamperMechanically controlled
Ridge-mounted gravity ventilators provide natural building ventilation. The identified assembly includes a bird screen and a mechanically controlled damper. The supplied details do not establish airflow capacity, unit dimensions or damper actuation specifications.
Price upon request

Sand Trap Louvers

Natural ventilation and sand interception share one louver assembly here. Rather than relying on an unspecified filter, these sand trap louvers use flashings arranged in a predetermined pattern to form the sand trap. The same arrangement is intended to allow air movement through the building opening.
Product typeSand trap louver
ConstructionArranged flashings
ConfigurationPredetermined flashing arrangement
FunctionsNatural ventilation and sand trapping
Sand trap louvers use flashings configured in a predetermined arrangement. The louver is intended to serve two functions at the building opening: natural airflow and sand interception. Size, material and measured airflow or trapping efficiency are not specified.
Price upon request

Designing and manufacturing Safe Structures for Storage Systems

An effective storage layout starts with the goods moving through the facility. Steel warehouse storage racking systems can be planned around inventory organisation, available space and material handling, with building design considered alongside racking needs. Capacity, finishes, equipment fit and supervision remain points to define for each project.
SystemSteel racking
ApplicationsWarehouse, logistics, retail and industrial storage
Planning approachCoordinated building and storage layout
Potential sectionsStructural profiles, built-up sections, cold-rolled members
Finishing discussionPowder-coated finishes
Service-scope discussionInstallation and commissioning supervision
Compatibility discussionPallets and material-handling equipment
Performance discussionLoad capacity and testing requirements
Steel storage racking is discussed for warehouse, logistics, retail and industrial settings. Planning coordinates storage layout, building structure and goods movement. Design-dependent members may include steel profiles, built-up sections or cold-rolled members. Finishes, load capacity, testing and supervision are project requirements to confirm.
Price upon request

Structural Steel – A great system to build heavy and complex structures

Workshop fabrication brings complex structural steel work into a controlled setting before installation. These hot rolled welded structural steel structures use custom-designed sections and assemblies for industrial, commercial and infrastructure projects. The approach can reduce on-site fabrication needs while supporting coordinated quality and project execution.
SystemCustom-designed structural steel
Section typeHot-rolled steel
AssembliesWelded
Fabrication approachWorkshop fabrication
ApplicationsIndustrial, infrastructure and commercial
Industrial examplesSteel, oil and gas, smelting, chemical, fertilizer and cement
Infrastructure examplesPower plants, airports, bridges and communication towers
Commercial examplesHigh-rises, complexes, malls and multiplexes
Custom structural steel frameworks combine hot-rolled sections and welded assemblies, with workshop fabrication for industrial, infrastructure and commercial projects. Applications include manufacturing facilities, power infrastructure, bridges and commercial buildings. Drawings, project location and construction requirements inform the proposed scope.
Price upon request

Fasteners

No. 14 self-drilling screws bring together a steel-wire construction and bonded EPDM washers. Available as plain carbon steel or stainless steel types, these No. 14 self drilling steel fasteners give buyers a defined screw family and material choice before individual dimensions are selected.
FastenerSelf-drilling screws
DesignationNo. 14
MaterialSteel wire
WasherBonded EPDM
Steel typesPlain carbon steel or stainless steel
No. 14 self-drilling fasteners are made from steel wire and incorporate bonded EPDM washers. Plain carbon steel and stainless steel versions are identified. Screw length, head configuration and tested performance values are not specified.
Price upon request

Louvers

A 1 m × 1 m standard size gives these adjustable blade louvers with insect screen a precise starting dimension. Overlapping blades admit airflow while blocking sunlight entry, and a hand crank with blade adjustment lever provides the named adjustment arrangement for the framed opening.
Blade arrangementAdjustable overlapping blades
FunctionsAllows airflow and blocks sunlight
Standard size1 m × 1 m
ScreenInsect screen
ControlHand crank
Adjustment componentBlade adjustment lever
These framed louvers use adjustable overlapping blades to permit airflow while blocking sunlight. Their stated standard size is 1 m × 1 m. An insect screen, hand crank and blade-adjustment lever are part of the assembly.
Price upon request

Pre-Engineered Steel Buildings (PEB)

Primary structural frames, cold-formed members, and roof and wall panels form the core of these pre engineered steel buildings PEB systems. Configurable options can include insulation, mezzanines, crane systems and selected building accessories. Kirby's engineering, fabrication and construction services support applications from warehouses to institutional buildings.
Building typePre-engineered steel buildings (PEB)
Primary structureStructural frames
Secondary structureCold-formed members
CladdingRoof and wall panels
Optional systemsSandwich panels, insulation, mezzanines and cranes
Possible accessoriesSkylights, wall lights, vents, louvers, roof monitors, doors and windows
Services mentionedEngineering, fabrication and construction
ApplicationsFactories, warehouses, retail, transport, offices and institutions
Pre-engineered steel buildings combine primary frames, cold-formed secondary members and roof/wall panels. The system is described for industrial, commercial and institutional projects. Insulation, sandwich panels, mezzanines, crane systems and openings or ventilation accessories are configurable options rather than standard inclusions.
Price upon request

Insulation

High-pressure-injected polyurethane foam is the defining material of these building insulation panels. They are CFC-free and self-extinguishing, with low water absorption and vapour transmission also indicated. Buyers evaluating heat and cold performance should obtain the relevant test classifications and numerical limits before selection.
FormatInsulation panels
MaterialPolyurethane foam
Manufacturing processHigh-pressure injection
Composition claimCFC-free
Fire behaviour claimSelf-extinguishing
Temperature claimWithstands intense heat and extremely low temperatures
Water performance claimVery low water absorption
Vapour performance claimVery low vapour transmission
Sheeting adhesion claimExcellent adhesion
Building insulation panels use high-pressure-injected polyurethane foam. They are CFC-free and self-extinguishing, with stated tolerance of intense heat and extreme cold, very low water absorption and vapour transmission, and excellent adhesion to panel sheeting. Quantified performance values are unavailable.
Price upon request

Aircraft Hangar Doors

Define the hangar opening and its framing together. Custom aircraft hangar doors and framing form part of the special-application solutions associated with Kirby, alongside separate possibilities for equipment-support systems and maintenance cranes. Each element needs a clearly agreed scope rather than an assumed standard package.
ApplicationAircraft hangars
Solution typeCustomized hangar doors and framing
Related project areaSupport systems for special equipment
Related project areaMaintenance cranes
Named provider in project scopeKirby
The special-application offering identifies customised aircraft-hangar doors and framing. Customised supports for specialised equipment and maintenance cranes are also discussed. Kirby is named in connection with these solutions; specific dimensions, operating systems and project inclusions remain undefined.
Price upon request

Power Ventilators

No wind does not have to mean no roof ventilation. These wind-independent power roof ventilators provide extraction when wind is absent through a low-silhouette Kirby 'C' whirlwind unit. A spun-aluminium non-return shutter and one-piece base and throat complete the roof-mounted arrangement.
Model referenceKirby ‘C’ whirlwind
ProfileLow silhouette
FunctionExtraction ventilation
ShutterSpun-aluminium non-return
Base and throatOne-piece
Operating claimVentilation when there is no wind
LocationTop of roof panels
Kirby 'C' whirlwind power ventilators are low-silhouette extract units installed above roof panels. They provide ventilation even when wind is absent and include a spun-aluminium non-return shutter and one-piece base-and-throat construction. Electrical and airflow ratings are unspecified.
Price upon request

Aluminum Windows

A single window need not remain an isolated unit. These double sliding aluminum windows have guide ways and jamb fins that control sliding movement; joining the jamb fins allows multiple windows to be formed. The standard size is 1 m × 1 m, with a half insect screen included.
MaterialAluminum
OperationDouble slide
Movement systemGuide ways and jamb fins
Window joiningMultiple windows formed by joining jamb fins
Standard size1 m × 1 m
ScreenHalf insect screen
PlacementBuilding walls
Aluminum wall windows use double-sliding operation guided by guide ways and jamb fins. Their stated standard size is 1 m × 1 m, with a half insect screen included. Jamb fins can be joined to create multi-window arrangements.
Price upon request
WhatsApp